1. Kirish
This manual provides detailed instructions for the safe installation, operation, and maintenance of the Fantech FG 10 Inline Centrifugal Duct Fan. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.
2. Xavfsizlik ma'lumotlari va ogohlantirishlar
OGOHLANTIRISH: Yong'in, elektr toki urishi yoki odamlarning shikastlanishi xavfini kamaytirish uchun quyidagilarga rioya qiling:
- Installation work and electrical wiring must be performed by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction.
- Before servicing or cleaning the unit, switch off power at the service panel and lock the service disconnecting means to prevent accidental power activation. If the service disconnecting means cannot be locked, securely fasten a prominent warning tag.
- Ducting air is essential for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back-drafting. Follow heating equipment manufacturer guidelines and safety standards from organizations like the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), as well as local code authorities.
- When cutting or drilling into walls or ceilings, avoid damaging electrical wiring and other hidden utilities.
- Kanalli fanatlar har doim ochiq havoga chiqarilishi kerak.
- If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- Hech qachon kalitni vannadan yoki dushdan yetib boradigan joyga qo'ymang.
- Safety guards must be installed if the fan is within 7 feet of the ground, within 7 feet of the working area, or when otherwise advisable for safety.
- FGC models are factory-wired with a power cord. If installing an FGC model outdoors, use only on GFCI protected receptacles. Do not use an extension cord with these models.
- All appropriate termination accessories (e.g., roof cap, wall cap, louvered shutters) are to be used with this fan.
3. Paketni ochish va tarkibi
Carefully remove the Fantech FG 10 fan from its packaging. Inspect the unit for any signs of damage that may have occurred during shipping. If any damage is found, contact your supplier immediately.
Paketda quyidagilar bo'lishi kerak:
- Fantech FG 10 Inline santrifüj kanalli fan
- Qo'llanma

Image 1: The Fantech FG 10 Inline Centrifugal Duct Fan as it appears in its packaging. The fan unit is shown on top of its cardboard box, which displays the model number and brand logo.
4. O'rnatish
The Fantech FG series fans are designed for easy installation and can be mounted at any angle, from horizontal to vertical, due to their compact design and straight-through airflow.
4.1 Fanni o'rnatish
The fan can be mounted using a mounting bracket or suspended with hanger straps.
- Using Mounting Bracket: Refer to Illustration 1 for bracket installation.
- Suspending with Hanger Straps: Refer to Illustration 2 for suspension method.
4.2 Kanal ulanishi
When connecting ductwork, ensure a good seal using duct clamps and duct outlet collars. If using Fantech FG clamps, attach them and insert screws through the clamp kirish va chiqish gardishlariga.
DIQQAT: Use 1/2" sheet metal screws to secure ductwork to the inlet and outlet. It is critical that screw penetration into the fan housing is no more than 1/2" to avoid damaging the impeller. It may be necessary to shield screws away from the impeller. If not using Fantech FG clamps, use 1/2" screws.

Image 2: Installation diagrams for Fantech FG series fans. Illustration 1 shows mounting with a bracket, while Illustration 2 details suspension using hanger straps and duct connection with clamps.
5. Elektr kabellari
All installation should be wired according to the following diagrams. Failure to comply will cause the motor to hum or not work.
5.1 Wiring with Speed Controller
For models requiring a speed controller, follow the provided wiring diagram carefully. Ensure all connections are secure and correct.
5.2 Wiring without Speed Controller
For models operating without a speed controller, refer to the specific wiring diagram for direct connection. FGC models are factory-wired with a power cord.

Image 3: This image displays special wiring precautions and diagrams for Fantech FG series fans, including configurations with and without a speed controller. It also includes a table of fan dimensions.
6. Operatsiya
Once properly installed and wired, the Fantech FG 10 fan is ready for operation. Ensure all safety precautions have been followed before powering on the unit. The fan is designed for continuous operation within its specified parameters.
The FG 10 model features 3 power levels and can be controlled remotely. Refer to the remote control instructions (if applicable) for specific operational details.
7. Xizmat ko'rsatish
The Fantech FG 10 fan requires minimal maintenance.
- The fan bearings are sealed and pre-lubricated, so no additional lubrication is necessary.
- Annually, remove any airborne particles that may have accumulated on the impeller. No other maintenance is typically required.
8. Muammolarni bartaraf qilish; nosozliklarni TUZATISH
If the fan fails to operate, check the following:
- Consult the included wiring diagrams to ensure proper connections.
- Verify motor lead wiring, incoming supply wiring, and capacitor connections.
- If possible, use a meter to test for continuity between fan leads. Note that a capacitor will not show a reading when tested with a meter.
9. Texnik shartlar
| Xususiyat | Spetsifikatsiya |
|---|---|
| Brend | FANTECH |
| Model nomi | FG 10 |
| Elektr fanining dizayni | Egzoz fan |
| Quvvat manbai | Havo quvvati |
| Mahsulot o'lchamlari | 6"D x 5"W x 7"Y |
| Element og'irligi | 10.6 funt |
| Tavsiya etilgan foydalanish | Charchaydi |
| Wattage | 138 vatt |
| Tugatish turi | Chelik |
| Havo oqimining hajmi | 515 kub fut/daqiqa (CFM) |
| jildtage | 120 volt |
| Kiritilgan komponentlar | Muxlis |
| Ichki/tashqi makonda foydalanish | Ochiq havoda |
| Nazorat usuli | Masofadan |
| Quvvat darajalari soni | 3 |
| Samaradorlik | 3.73 cfm/watt |
9.1 Dimensional Information
Refer to the diagram in Image 3 for detailed dimensional measurements (A, C, D, E, F) corresponding to various FG fan models, including the FG 10.
10. Kafolat va qo'llab-quvvatlash
For warranty information, please refer to the documentation provided with your purchase or visit the official Fantech website. For technical support or inquiries, please contact Fantech customer service.
Fantech aloqa ma'lumotlari:
Your Ventilation Solutions Company
10048 Industrial Drive
Laurel, DE 19956
AQSh
www.fantech.net