Attwood 1671-1

Attwood 90 Degree Fuel Tank Vent Instruction Manual

Model: 1671-1

Mahsulot tugadiview

The Attwood 90 Degree Fuel Tank Vent (Model 1671-1) is engineered to prevent water from entering the fuel tank while ensuring air can vent freely. This design is critical during normal sea conditions and washdowns, effectively eliminating the requirement for an anti-siphon loop in the vent hose. This product adheres to ABYC Standard requirements, ensuring reliable performance and safety. It is constructed from durable, flame-retardant black plastic and features a white vent head/cover.

Attwood 90 Degree Fuel Tank Vent, black with white head

Image: Attwood 90 Degree Fuel Tank Vent, showing its black body and white vent head. This component is essential for proper fuel tank ventilation and water prevention.

Texnik xususiyatlari

Qism raqami1671-1
Shlangi mosligi5/8" I.D.
Korpusning maksimal qalinligi9/16"
O'rnatish teshigi o'lchami3/4"
MaterialFlame-retardant black plastic, Stainless Steel (for vent head option)
Olchamlari (U x G x Y)7.5 x 12.5 x 4.5 dyuym
Element og'irligi1.6 untsiya
UPC022697167118

O'rnatish va o'rnatish

The Attwood 90 Degree Fuel Tank Vent is designed for straightforward and permanent installation. Follow these steps for proper setup:

  1. Tayyorlanishi: Identify the optimal location on the hull for the vent. Ensure the area is clean, free of obstructions, and that the hull thickness does not exceed 9/16 inches at the chosen point.
  2. Teshikni burg'ulash: Using a drill bit appropriate for your hull material, create a 3/4 inch diameter hole at the marked installation spot. Ensure the hole is clean and smooth, without burrs.
  3. Vent Placement: Insert the main body of the vent into the drilled hole from the exterior of the hull. Orient the vent so that the 90-degree bend correctly positions the hose connection point for your fuel system's routing.
  4. Xavfsiz ulanish: From the interior of the hull, connect a 5/8 inch I.D. fuel vent hose to the vent's barb fitting. Secure the hose firmly with a marine-grade hose clamp to prevent any leaks and ensure a robust seal.
  5. Yakuniy tekshirish: Verify that the vent head is securely seated against the hull and that the hose connection is tight. Conduct a system check to confirm proper fuel tank ventilation and the absence of any fuel or air leaks.

Eslatma: The unique design of this vent eliminates the need for an anti-siphon loop in the vent hose, as it effectively prevents water ingress while allowing unrestricted air flow.

Faoliyat tamoyillari

The Attwood 90 Degree Fuel Tank Vent functions on a precise mechanism to maintain optimal fuel tank pressure and prevent water contamination:

Xizmat

The Attwood 90 Degree Fuel Tank Vent is designed for low maintenance. Regular visual inspections are recommended to ensure its continued optimal performance and longevity.

Muammolarni bartaraf qilish; nosozliklarni TUZATISH

If you encounter issues with your fuel tank ventilation system, consider the following common problems and their potential solutions:

For persistent or complex issues that cannot be resolved with these steps, it is highly recommended to consult a qualified marine technician.

Kafolat haqida ma'lumot

Attwood products are manufactured to rigorous quality standards. For specific warranty details pertaining to your 90 Degree Fuel Tank Vent (Model 1671-1), please refer to the official Attwood website or contact Attwood customer support directly. Warranty terms typically cover defects in materials and workmanship under normal use and service conditions.

Mijozlarni qo‘llab-quvvatlash

For further assistance, technical inquiries, or to report a product issue, please reach out to Attwood customer support. Provide your product model number for efficient service.

Tegishli hujjatlar - 1671-1

Oldindanview Attwood 90° P-Trap shamollatgichni o'rnatish bo'yicha qo'llanma va kafolat
Attwood 90° P-Trap Vent (Modellar 1670, 1671, 1674) uchun keng qamrovli o'rnatish ko'rsatmalari, texnik qo'llanma va kafolat tafsilotlari. EPK muvofiqligi va dengiz xavfsizligi standartlari haqida bilib oling.
Oldindanview Attwood Sahara Mk2 avtomatik sintine nasoslarini o'rnatish va ishlatish bo'yicha qo'llanma
Attwood Sahara Mk2 avtomatik sintine nasoslari uchun keng qamrovli qo'llanma (Modellar S500, S800, S1200). Xavfsizlik bo'yicha ogohlantirishlar, o'rnatish yo'riqnomalari, ulanish sxemalari, ishlash xususiyatlari va kafolat ma'lumotlarini o'z ichiga oladi.
Oldindanview Attwood Tsunami Mk2 500 GPH bilge nasosi va o'rnatish to'plami | Ishonchli dengiz bilge nasosi
Attwood Tsunami Mk2 500 GPH bilge nasosi va o'rnatish to'plamini kashf eting. Ptentli X-Air™ havo blokirovkasiga qarshi texnologiya, 40% yaxshilangan himoya va dengizda foydalanish uchun qulay o'rnatish. To'liq texnik xususiyatlar va to'plam tarkibini o'z ichiga oladi.
Oldindanview Attwood PowerBase 6100 seriyali quvvatli buklanadigan yorug'lik va antenna bazasini o'rnatish bo'yicha qo'llanma
Attwood PowerBase 6100 Series uchun keng qamrovli o'rnatish, simlarni ulash, texnik xizmat ko'rsatish va muammolarni bartaraf etish bo'yicha qo'llanma, dengiz ilovalari uchun quvvatli buklanadigan yorug'lik va antenna bazasi.
Oldindanview Attwood PowerBase 6100 seriyali quvvatli buklanadigan yorug'lik va antenna bazasini o'rnatish bo'yicha qo'llanma
Ushbu qo'llanmada Attwood PowerBase 6100 Series Powered Down Light va Antenna bazasini o'rnatish bo'yicha batafsil ko'rsatmalar berilgan. U o'rnatish joyi, simlar, chiroqlar va antennalarni o'rnatish, sinov, texnik xizmat ko'rsatish va kafolat ma'lumotlarini qamrab oladi.
Oldindanview Attwood T500 Recirq Livewell Aerator Kit Installation Instructions
This document provides installation instructions for the Attwood T500 Recirq Livewell Aerator Kit, model 4253. It covers features, warnings, required materials, mounting location selection, pump and aerator head installation, hose installation, wiring instructions, and care and maintenance.