Juniper Networks EX2200-24T-4G

Juniper EX2200-24T-4G 3-qavatli kalit foydalanuvchi qo'llanmasi

Model: EX2200-24T-4G

1. Kirish

This manual provides essential information for the installation, operation, and maintenance of your Juniper EX2200-24T-4G Layer 3 Switch. The EX2200 series switches are designed to deliver high-performance, wire-rate forwarding capabilities, even with advanced control plane features enabled. This device incorporates an application-specific integrated circuit (ASIC)-based Packet Forwarding Engine (PFE) with an integrated CPU, ensuring consistent performance and reliability.

2. Mahsulot tugadiview

The Juniper EX2200-24T-4G is a compact, high-performance Layer 3 Ethernet switch. It features 24 10/100/1000BASE-T Gigabit Ethernet ports for network connectivity and 4 Gigabit Ethernet SFP (Small Form-Factor Pluggable) uplink ports for fiber optic connections to other network devices or the core network.

Old view of the Juniper EX2200-24T-4G Layer 3 Switch, showing 24 RJ45 Ethernet ports and 4 SFP uplink ports.

1-rasm: Front panel of the Juniper EX2200-24T-4G switch. This image displays the front panel of the Juniper EX2200-24T-4G switch. It features 24 RJ45 Gigabit Ethernet ports, numbered 0 through 23, arranged in two rows. To the right, there are four SFP (Small Form-Factor Pluggable) uplink ports, typically used for fiber optic connections. Status LEDs for system (SYS), alarm (ALM), speed (SPD), duplex (DX), enable (EN), and Power over Ethernet (POE) are also visible on the right side. Note that this specific model (EX2200-24T-4G) does not support PoE.

2.1 Asosiy xususiyatlar

  • 24 x 10/100/1000BASE-T Ethernet ports
  • 4 x Gigabit Ethernet SFP uplink ports
  • Layer 3 switching capabilities
  • Junos operating system
  • Rakka o'rnatiladigan ixcham 1U dizayn

3. Sozlash

3.1 Paketni ochish

Carefully remove the switch and all accessories from the packaging. Verify that all components listed in the packing list are present. Retain the packaging materials for future use or transport.

3.2 O'rnatish

The EX2200-24T-4G switch can be deployed as a desktop unit or rack-mounted. For rack mounting, use the provided rack-mount kit and secure the switch in a standard 19-inch equipment rack. Ensure adequate airflow around the device for proper cooling.

3.3 Quvvatni ulash

  1. Connect one end of the provided AC power cord to the AC power receptacle on the rear panel of the switch.
  2. Connect the other end of the power cord to a grounded AC power outlet.
  3. Ensure the power source provides the correct voltage (240 volt).

3.4 Tarmoq kabellarini ulash

  • RJ45 portlari: Connect standard Ethernet cables (Cat5e or higher) from your network devices (computers, servers, access points) to the 24 RJ45 ports on the front panel.
  • SFP Uplink Ports: Insert compatible SFP transceivers into the 4 SFP uplink ports. Connect fiber optic cables from these transceivers to your core network or other switches.

3.5 Dastlabki konfiguratsiyaga kirish

To perform initial configuration, connect a console cable (RJ-45 to DB-9) from your management workstation to the console port on the switch. Use a terminal emulation program (e.g., PuTTY, Tera Term) with the following settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control. Alternatively, if the switch has a default management IP, you can connect via a web browser or SSH after basic network connectivity is established.

4. Operatsion

4.1 Quvvatni yoqish/o‘chirish

Once the power cord is connected, the switch will automatically power on. There is no separate power button. To power off, disconnect the power cord from the AC outlet.

4.2 LED ko'rsatkichlari

The front panel LEDs provide status information about the switch and its ports:

  • SYS (Tizim): Indicates overall system status. Green for normal operation, amber for a fault.
  • ALM (Alarm): Signal holatini bildiradi.
  • SPD (Tezlik): Indicates the link speed of the corresponding port.
  • DX (Duplex): Indicates the duplex mode (half or full) of the corresponding port.
  • EN (Enable): Indicates if the port is enabled.
  • POE (Power over Ethernet): This LED is present but not functional on the EX2200-24T-4G model as it does not support PoE.

4.3 Junos OS

The switch runs on Juniper Networks' Junos operating system. Configuration and management are primarily performed via the command-line interface (CLI) accessible through the console port or SSH. Junos provides a robust and feature-rich environment for network management.

5. Xizmat ko'rsatish

5.1 Tozalash

Keep the switch clean and free of dust. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners directly on the device. Ensure ventilation openings are clear of obstructions.

5.2 Mikrodasturlarni yangilash

Juniper Networks qo'llab-quvvatlashini vaqti-vaqti bilan tekshirib turing website for available Junos OS updates. Firmware updates can provide new features, performance enhancements, and security patches. Follow the instructions provided by Juniper Networks for the update process.

5.3 Atrof-muhitga oid mulohazalar

Operate the switch within its specified environmental limits (temperature, humidity). Ensure proper ventilation to prevent overheating. Avoid exposing the device to direct sunlight, excessive moisture, or extreme temperatures.

6. Muammolarni bartaraf qilish; nosozliklarni TUZATISH

6.1 Quvvat yo'q

  • Verify the power cord is securely connected to both the switch and the AC outlet.
  • Elektr rozetkasining ishlashiga ishonch hosil qilish uchun boshqa qurilma bilan tekshiring.
  • Quvvat manbai voltage matches the switch's requirements (240 Volts).

6.2 Portda havola yo'q

  • Check the Ethernet cable for damage and ensure it is properly seated in both the switch port and the connected device.
  • Ulangan qurilma yoqilganligini va to'g'ri ishlayotganini tekshiring.
  • Check the port configuration in Junos OS to ensure it is enabled and correctly configured.
  • For SFP ports, ensure the transceiver is correctly inserted and compatible, and the fiber optic cable is clean and undamaged.

6.3 System Alarm (ALM LED)

If the ALM LED is lit, consult the Junos OS documentation or the Juniper Networks support website for specific alarm codes and recommended actions. This typically indicates a hardware fault or a critical system event.

7. Texnik shartlar

XususiyatSpetsifikatsiya
Model raqamiEX2200-24T-4G
BrendJuniper tarmoqlari
Ethernet portlari24 x 10/100/1000BASE-T (RJ45)
Yuqori ulanish portlari4 x Gigabit Ethernet SFP
Interfeys turiRJ45, SFP
Ma'lumot uzatish tezligi1000 Megabit / soniya
Operatsion tizimJunos
jildtage240 volt
Mahsulot o'lchamlari (LxWxH)10 x 17.4 x 1.75 dyuym
Element og'irligi6 funt
Kiritilgan komponentlarSwitch, Accessories
Ishlab chiqaruvchiArcha
UPC832938043305

8. Qo'llab -quvvatlash va kafolat

8.1 Texnik yordam

For technical assistance, documentation, and software downloads, please visit the official Juniper Networks support website. You can find resources such as knowledge base articles, community forums, and contact information for customer support.

8.2 Mahsulot kafolati

This Juniper Networks product is covered by a standard manufacturer's warranty. Details regarding the warranty period and terms can be found on the Juniper Networks official website or in the warranty documentation included with your purchase. Please retain your proof of purchase for warranty claims.

Tegishli hujjatlar - EX2200-24T-4G

Oldindanview Juniper Networks Junos OS for EX Series Ethernet Switches: Power over Ethernet (PoE) Guide
This document provides comprehensive information on configuring and managing Power over Ethernet (PoE) for Juniper Networks EX Series Ethernet Switches running Junos OS. It covers an overview of PoE, configuration tasks, administration, and troubleshooting.
Oldindanview Junos OS for EX Series Ethernet Switches: Virtual Chassis Configuration Guide
This document provides comprehensive configuration details and operational commands for Juniper Networks EX Series Ethernet Switches, focusing on the implementation and management of Virtual Chassis technology. It covers setup, troubleshooting, and advanced features for models EX2200, EX3300, EX4200, EX4500, and EX4550.
Oldindanview Juniper EX3300 Switch Hardware Guide
This guide provides comprehensive information on the Juniper Networks EX3300 Ethernet Switch hardware, covering installation, configuration, maintenance, and troubleshooting. Learn about system overview, chassis components, power, cooling, site planning, and safety guidelines for the EX3300 series.
Oldindanview Juniper EX3400 kommutator uskunalari qo'llanmasi: o'rnatish, sozlash va texnik xizmat ko'rsatish
Juniper Networks EX3400 seriyali Ethernet kommutatorlari uchun korporativ tarmoqlarni joylashtirish uchun o'rnatish, o'rnatish, quvvatlantirish, ulanish, texnik xizmat ko'rsatish, muammolarni bartaraf etish va xavfsizlikni qamrab oluvchi keng qamrovli apparat qo'llanmasi.
Oldindanview Juniper Networks EX2300 Switch Hardware Guide: Installation and Configuration
Comprehensive hardware guide for Juniper Networks EX2300 Ethernet Switches. Learn about installation, configuration, maintenance, and troubleshooting for enterprise and data center networking solutions.
Oldindanview Juniper EX4300 Ethernet kommutatorlari: Ma'lumotlar jadvali
Juniper EX4300 seriyali Ethernet kommutatorlari uchun batafsil ma'lumotlar jadvali, batafsil xususiyatlar, texnik xususiyatlar, virtual shassi texnologiyasi va korporativ boshqaruv imkoniyatlariampAQSh va ma'lumotlar markazi tarmoqlari.