Dwyer A3000 Series

Dwyer Photohelic A3000 seriyali bosim o'tkazgichi/o'lchagichi uchun qo'llanma

Model: A3000 seriyali

1. Kirish

The Dwyer Photohelic Series A3000 Pressure Switch/Gauge is a versatile instrument that combines the functions of a precise pressure gauge with highly repeatable pressure switches. Utilizing the proven Magnehelic gauge design, this device accurately measures and controls positive, negative, or differential pressures of air and compatible gases.

It features two phototransistor-actuated, DPDT relays for low/high limit control, allowing for precise system management. Set points are easily adjustable via knobs located on the gauge face. The continuous gauge reading remains unaffected by switch operation, even during power loss, ensuring reliable monitoring.

2. Xususiyatlari

  • Combined Functionality: Operates as both a pressure gauge and a pressure switch.
  • Aniq o'lchov: Employs the Magnehelic gauge design for accurate pressure readings.
  • Dual Control Relays: Includes two phototransistor-actuated DPDT relays for low/high limit control.
  • Adjustable Set Points: Easy-to-adjust set point indicators via front-mounted knobs.
  • Continuous Reading: Gauge reading is continuous and independent of switch operation or power status.
  • Optical Limit Switches: Utilizes optical limit switches for enhanced reliability and extended service life.
  • Variable Deadband: Set points can be interlocked to provide a variable deadband, suitable for fan or dampnazorat qilish.
  • Kuchli qurilish: Features a clear polycarbonate plastic cover and a light shield to protect internal components and ensure clear visibility.

3. O'rnatish va o'rnatish

Proper installation is crucial for the accurate and reliable operation of your Photohelic Switch/Gauge. Refer to the detailed wiring diagrams and mounting instructions provided with your specific model for complete guidance.

3.1 O'rnatish

The unit is designed for vertical position calibration. Ensure the mounting surface is stable and free from excessive vibration. Secure the gauge using appropriate fasteners through the designated mounting holes.

3.2 Bosimli ulanishlar

Connect pressure lines to the appropriate ports on the gauge. Ensure all connections are sealed properly to prevent leaks, which can affect measurement accuracy. The gauge is suitable for air and compatible gases.

3.3 Elektr aloqalari

Connect the power supply and control circuits to the DPDT relays as per the electrical schematic. Ensure all wiring complies with local electrical codes and safety standards. The optical limit switches are designed for reliability and precise switching accuracy.

Dwyer Photohelic Series A3000 Pressure Switch/Gauge with clear cover, showing internal components, gauge face, and control knobs.

1-rasm: Dwyer Photohelic Series A3000 Pressure Switch/Gauge. This image displays the device with its clear polycarbonate cover, revealing the internal circuitry, the pressure gauge face calibrated for vertical position, and the two set point adjustment knobs labeled "ZERO". The gauge face indicates a maximum pressure of 25 PSIG.

4. Operatsiya

4.1 Quvvat yoqilgan

Once installed and wired, apply power to the unit. The gauge pointer will indicate the current pressure.

4.2 Nolni sozlash

Before operation, ensure the gauge reads zero when no pressure is applied. Use the "ZERO" adjustment screw (typically located on the front cover or near the bottom of the gauge face) to calibrate the pointer to zero.

4.3 Setting Control Points

  1. Identify the two set point knobs on the front of the gauge. These control the low and high limit switches.
  2. Rotate the desired knob to move its corresponding red set point indicator to the required pressure value on the gauge face.
  3. When the actual pressure (indicated by the main pointer) crosses a set point indicator, the associated DPDT relay will actuate, triggering the connected control circuit.
  4. The individual set point deadband is approximately one pointer width, which is less than 1% of the full scale.
  5. For applications requiring a variable deadband, the set points can be interlocked according to specific wiring diagrams.

4.4 Reading the Gauge

The gauge provides a continuous visual indication of the measured pressure. The scale is typically in inches of water column (WC) or pounds per square inch (PSIG), depending on the model. For example, the gauge face shown in Figure 1 indicates a range up to 0.50 inches of water, with markings at .20, .30, .40, and .50.

5. Xizmat ko'rsatish

The Dwyer Photohelic Switch/Gauge is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

  • Tozalash: Keep the exterior of the gauge clean. Use a soft, damp cloth to wipe the clear cover. Avoid abrasive cleaners or solvents.
  • Kalibrlash tekshiruvi: Periodically verify the zero point and accuracy of the gauge using a known pressure source. Recalibrate if necessary.
  • Ulanishning yaxlitligi: Inspect all pressure and electrical connections for tightness and signs of wear or corrosion.
  • Atrof-muhit sharoitlari: Ichki qismlarga zarar yetkazmaslik uchun ish muhiti belgilangan harorat va namlik oralig'ida ekanligiga ishonch hosil qiling.

6. Muammolarni bartaraf qilish; nosozliklarni TUZATISH

If you encounter issues with your Photohelic Switch/Gauge, consider the following common troubleshooting steps:

  • No Gauge Reading:
    • Check pressure connections for leaks or blockages.
    • Verify that pressure is being applied to the correct ports.
  • Incorrect Gauge Reading:
    • Perform a zero adjustment.
    • Check for proper calibration against a known standard.
    • Ensure the gauge is mounted in a vertical position as calibrated.
  • Switches Not Actuating:
    • Jihozning elektr quvvatini tekshiring.
    • Check wiring to the DPDT relays.
    • Ensure set points are correctly positioned relative to the current pressure.
    • Inspect optical limit switches for any obstructions or damage.
  • Vaqti-vaqti bilan ishlash:
    • Bo'shashgan elektr ulanishlarini tekshiring.
    • Barqaror elektr ta'minotini ta'minlang.
    • Verify environmental conditions are stable and within operating limits.

If problems persist, contact Dwyer technical support for assistance.

7. Texnik shartlar

ParametrQiymat
Model raqamiA3001AV (Specific model example)
Bosim diapazonlariVarious, from 0-.25" WC up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar)
Maks. Ish bosimiStandard models: 25 psig (1.7 bar); Options: 35 (2.4) or 80 (5.5 bar) psig; 36000S models: 6000 psig (413 bar)
Kommutator turiTwo phototransistor actuated, DPDT relays
O'lik band nuqtasini o'rnatingLess than 1% of full scale (one pointer width)
Media mosligiHavo va mos gazlar
MaterialPlastic (cover)
Element og'irligi4.7 funt (taxminan)
Ishlab chiqaruvchiDwyer asboblari

8. Kafolat va qo'llab-quvvatlash

For warranty information, technical support, or service inquiries, please contact Dwyer Instruments directly. Refer to the official Dwyer website or your purchase documentation for the most current contact details and warranty terms.

Dwyer Instruments, Inc.
www.dwyer-inst.com

Tegishli hujjatlar - A3000 seriyali

Oldindanview Dwyer A3000 seriyali fotogel differentsial bosim o'tkazgichi/o'lchagichi foydalanuvchi qo'llanmasi
Dwyer Series A3000 Fotospiral Differentsial Bosim O'lchagichi/O'lchagichi uchun foydalanuvchi qo'llanmasi, uning texnik xususiyatlari, o'rnatilishi, elektr ulanishlari va texnik xizmat ko'rsatish batafsil tavsifi.
Oldindanview Dwyer Magnehelic® Differensial bosim o'lchagich (HP/MP) - Texnik xususiyatlari va ko'rsatmalari
Dwyer's Magnehelic® yuqori va o'rta bosimli differentsial bosim o'lchagichlari uchun texnik xususiyatlar, o'rnatish va ishlatish yo'riqnomalari (A-27-HP-MP byulleteni). Model tafsilotlari, aniqlik, harorat oralig'i, o'rnatish, ulanishlar va aksessuarlarni o'z ichiga oladi.
Oldindanview Dwyer seriyali 490W simsiz gidronik differentsial bosim manometri: O'rnatish va ishlatish bo'yicha qo'llanma
Dwyer seriyali 490W simsiz gidronik differentsial bosim manometri uchun texnik xususiyatlar, o'rnatish, ishlatish, muammolarni bartaraf etish va texnik xizmat ko'rsatishni qamrab oluvchi keng qamrovli qo'llanma. Gidronik tizimni aniq muvozanatlash uchun simsiz o'zgartirgichlar mavjud.
Oldindanview Dwyer Series 616KX Differensial bosim o'tkazgich - Tez boshlash qo'llanmasi
Dwyer Series 616KX Differensial bosim o'tkazgichi uchun tezkor boshlash qo'llanmasi, o'rnatish, simlarni ulash va nol kalibrlashni qamrab oladi. 2 simli va 3 simli konfiguratsiyalar uchun ulanish sxemalarini o'z ichiga oladi.
Oldindanview Dwyer Series 616KX Differensial bosim o'tkazgich foydalanuvchi uchun qo'llanma
Dwyer Series 616KX Differensial Bosim O'tkazgich uchun foydalanuvchi qo'llanmasi, batafsil o'rnatish, texnik xususiyatlar, elektr ulanishlari, ishlash, nol sozlash, chiqish signali konfiguratsiyasi, ehtiyot choralari, texnik xizmat ko'rsatish va kafolat ma'lumotlari.
Oldindanview Dwyer Series 616KX Differensial bosim o'tkazgich foydalanuvchi uchun qo'llanma
Dwyer Series 616KX Differentsial Bosim Transmitterining foydalanuvchi qo'llanmasi, unda o'rnatish, texnik xususiyatlar, elektr ulanishlari, nol sozlash, chiqish signalining o'zgarishi, ehtiyot choralari va kafolat ma'lumotlari keltirilgan.