1. Kirish
The GIMA OXY 6 Finger Pulse Oximeter is a portable device designed for non-invasive spot-checking of arterial oxygen saturation (SpO2) and pulse rate. It is suitable for use in medical and hospital environments, as well as for personal use under medical guidance. This manual provides essential information for the safe and effective operation of the device.
2. Xavfsizlik ma'lumotlari
Please read all safety warnings and precautions before using the device. Failure to do so may result in inaccurate readings or device malfunction.
- This device is intended for spot-checking and not for continuous monitoring.
- Oksimetrni MRI yoki KT muhitida ishlatmang.
- Qurilmani suv va namlikdan uzoqroq tuting.
- Consult a medical professional for interpretation of readings. This device is not a substitute for professional medical advice.
- Ensure the finger is clean and free of nail polish or artificial nails, as these can affect accuracy.
- Avoid excessive movement during measurement to ensure stable readings.
3. Mahsulot tugadiview
The GIMA OXY 6 features a high-resolution OLED color display showing SpO2, pulse rate, pulse bar graph, perfusion index (PI), and battery level. It is designed for ease of use with a compact form factor.

1-rasm: Old view of the GIMA OXY 6 Pulse Oximeter, displaying SpO2 and pulse rate values on its screen.
3.1. Paket tarkibi

2-rasm: The package includes the GIMA OXY 6 Pulse Oximeter, a plastic case, AAA batteries, and a lanyard.
- GIMA OXY 6 Pulse Oximeter
- 2 x AAA batareyalar
- Plastik tashish qutisi
- Lanyard
- Qo'llanma

3-rasm: The GIMA OXY 6 Pulse Oximeter attached to a lanyard, demonstrating its portability and ease of carrying.
4. Sozlash
4.1. Batareyani o'rnatish
- Qurilmaning orqa tomonida joylashgan batareya bo'limi qopqog'ini oching.
- Insert two AAA batteries according to the polarity indicators (+/-) inside the compartment.
- Batareya bo'limi qopqog'ini mahkam yoping.

4-rasm: Open battery compartment showing placement for two AAA batteries.
5. Foydalanish bo'yicha ko'rsatmalar
5.1. O'lchovni qabul qilish
- Ensure the device has fresh batteries installed.
- Cl ni ochingamp of the oximeter.
- Insert one finger (preferably the index, middle, or ring finger) into the rubber opening of the oximeter, ensuring the finger is fully inserted and resting on the sensor. The recommended finger thickness for this model is 1-22 mm.
- Cl-ni qo'yib yuboringamp. The device will automatically turn on and begin measurement.
- Keep your hand still during the measurement. Avoid bending your finger or making hand movements.
- Readings for SpO2, Pulse Rate, and Perfusion Index (PI) will appear on the display within a few seconds.

5-rasm: The GIMA OXY 6 Pulse Oximeter correctly placed on a finger for measurement.
5.2. Displeyni tushunish
- SpO2: Peripheral Oxygen Saturation, displayed as a percentage.
- PR: Pulse Rate, displayed in beats per minute (bpm).
- PI: Perfusion Index, a numerical value indicating the strength of the pulse signal at the sensor site.
- Pulse Bar Graph: Visual representation of pulse strength.
- Batareya ko'rsatkichi: Joriy batareya darajasini ko'rsatadi.
5.3. Automatic Power Off
The device will automatically power off after approximately 8 seconds of inactivity or when the finger is removed.
5.4. Kam hajmlitage signal
Batareya hajmi qachontage is low, a low voltage alarm will be indicated on the display. Replace the batteries promptly to ensure accurate operation.
5.5. Ovozli qo'llanma
The GIMA OXY 6 features an 8-language voice guide (English, French, Italian, Spanish, Greek, Portuguese, Arabic) for enhanced usability. Refer to the full manual for specific instructions on activating and changing voice guide settings.
6. Xizmat ko'rsatish
6.1. Tozalash
- Clean the surface of the oximeter with a soft cloth dampened with medical alcohol (70% ethanol or isopropanol).
- Do not immerse the device in water or any cleaning solution.
- Ensure the device is completely dry before reuse.
6.2. Batareyani almashtirish
Ovoz past bo'lganda batareyalarni almashtiringtage indicator appears. Always use two new AAA alkaline batteries. Dispose of used batteries according to local regulations.
6.3. Saqlash
Store the oximeter in its plastic carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
7. Muammolarni bartaraf qilish; nosozliklarni TUZATISH
| Muammo | Mumkin sabab | Yechim |
|---|---|---|
| Yoqilgandan keyin displey yo'q | Batareyalar o'lik yoki noto'g'ri o'rnatilgan. | Replace batteries or re-install them correctly, observing polarity. |
| Noto'g'ri o'qishlar | Finger not properly inserted; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm the finger. |
| "Finger Out" or similar error message | Finger not detected or improperly placed. | Ensure finger is fully inserted and resting on the sensor. |
| Qurilma kutilmaganda o'chadi | Low battery; automatic power-off due to inactivity. | Replace batteries; ensure finger is inserted for measurement. |
8. Texnik shartlar
| Model raqami | 34285 (OXY 6) |
| Displey turi | OLED Color Display |
| O'lchov parametrlari | SpO2, Pulse Rate, Perfusion Index (PI) |
| SpO2 Measurement Range | (Typical range, refer to device for exact range) |
| Puls tezligini o'lchash diapazoni | (Typical range, refer to device for exact range) |
| Aniqlik | High precision and repeatability with noise suppression |
| Quvvat talablari | 2 x AAA 1.5V ishqoriy batareyalar |
| Batareya muddati | Approximately 3 hours of continuous operation with full batteries |
| Olchamlari (U x G x Y) | 16 x 5.5 x 10 sm |
| Og'irligi | 200 gramm (batareyalar bilan birga) |
| Finger Thickness Range | 1-22 mm |
| Ovozli qo'llanma | 8 languages (GB, FR, IT, ES, GR, PT, Arabic) |
9. Kafolat va qo'llab-quvvatlash
Information regarding specific warranty terms and customer support for the GIMA OXY 6 Pulse Oximeter is not provided in this document. Please refer to the product packaging or contact GIMA customer service for details.