Anderson Power Products 5915-BK

Anderson Power Products 5915-BK PowerPole Contact Instruction Manual

Model: 5915-BK

1. Kirish

This manual provides essential instructions for the proper use, installation, and maintenance of Anderson Power Products 5915-BK PowerPole contacts. These contacts are designed for reliable electrical connections in various applications, supporting 10 or 12 AWG wire and rated for up to 75 amperes.

Please read this manual thoroughly before proceeding with installation or use to ensure safety and optimal performance.

2. Mahsulot tugadiview

The Anderson Power Products 5915-BK is a non-insulated copper contact specifically engineered for use with Anderson PowerPole connectors. Key features include:

  • Sim o'lchagich mosligi: Designed for 10 AWG (American Wire Gauge) and 12 AWG wires.
  • Joriy reyting: Capable of handling up to 75 Amperes.
  • Material: Constructed from high-conductivity copper for efficient power transfer.
  • Ulanish turi: Crimp terminal for secure and durable wire attachment.
  • Ilova: Integral component for creating custom PowerPole cable assemblies.
Anderson Power Products 5915-BK PowerPole Contact

Figure 1: Anderson Power Products 5915-BK PowerPole Contact. This image shows a single copper contact, designed for crimping onto 10 or 12 AWG wire. The contact features a flat, spade-like end for insertion into a PowerPole housing and a cylindrical barrel for wire crimping.

3. Xavfsizlik ma'lumotlari

Always observe the following safety precautions when working with electrical components:

  • Quvvatni uzish: Ensure all power sources are disconnected before installing or servicing electrical connections.
  • Tegishli vositalar: Use appropriate crimping tools designed for the specified wire gauge and contact type to ensure a secure connection.
  • Tel o'lchagich: Match the wire gauge to the contact's specifications (10-12 AWG) to prevent overheating or poor connections.
  • Izolyatsiya: Although these contacts are non-insulated, ensure proper insulation is applied to exposed wires and connections after assembly, typically by using PowerPole housings.
  • Professional o'rnatish: If you are unsure about any aspect of the installation, consult a qualified electrician.

4. O'rnatish va o'rnatish

Follow these steps to properly install the 5915-BK PowerPole contact onto your wire:

  1. Prepare Wire: Strip approximately 1/4 to 3/8 inch (6-9 mm) of insulation from the end of your 10 or 12 AWG wire. Ensure the wire strands are clean and untwisted.
  2. Simni kiritish: Insert the stripped end of the wire fully into the barrel of the 5915-BK contact. The wire strands should be visible through the inspection hole (if present) or reach the end of the barrel.
  3. Crimp Contact: Using a suitable crimping tool for PowerPole contacts, crimp the contact barrel securely onto the wire. Ensure a firm, permanent connection. A good crimp will be mechanically strong and electrically sound.
  4. Inspect Crimp: Visually inspect the crimp for any loose strands or improper deformation. Gently tug on the wire to confirm it is securely held by the contact.
  5. Assemble into Housing (Optional): If using with PowerPole housings (sold separately), insert the crimped contact into the appropriate housing cavity until it clicks into place. Ensure correct polarity.

For optimal performance, always use a dedicated PowerPole crimping tool.

5. Foydalanish bo'yicha ko'rsatmalar

Once the contacts are properly crimped onto wires and assembled into PowerPole housings (if applicable), they are ready for use. PowerPole connectors are designed for quick and reliable connection and disconnection.

  • Ulanmoqda: Align the PowerPole connectors (with contacts inserted) and push them firmly together until they lock. Ensure correct polarity (typically red for positive, black for negative).
  • Ulanish: Pull the PowerPole connectors apart with a firm, steady motion. Avoid pulling directly on the wires.

These contacts are designed for high current applications, ensuring minimal resistance and heat generation when properly installed.

6. Xizmat ko'rsatish

Anderson Power Products 5915-BK contacts require minimal maintenance. However, periodic inspection can help ensure long-term reliability:

  • Vizual tekshirish: Periodically check contacts and connections for signs of corrosion, discoloration, or physical damage.
  • Tozalik: Keep contacts free from dirt, dust, and moisture. Use a clean, dry cloth for cleaning.
  • Xavfsiz ulanishlar: Ensure that contacts remain securely seated within their housings and that crimps are still firm.
  • Haddan tashqari yuklanishdan saqlaning: 75 dan oshmang Ampere rating to prevent overheating and potential damage.

7. Muammolarni bartaraf qilish; nosozliklarni TUZATISH

If you experience issues with your PowerPole connections, consider the following:

  • Poor Connection/Intermittent Power:
    • Check crimp quality: Ensure the wire is securely crimped to the contact. Re-crimp if necessary.
    • Verify contact seating: Make sure the contact is fully inserted and locked into the PowerPole housing.
    • Inspect for corrosion: Clean any corrosion on the contact surfaces.
  • Overheating Connections:
    • Check wire gauge: Ensure the wire gauge (10 or 12 AWG) is appropriate for the current draw.
    • Verify current draw: Confirm that the current flowing through the connection does not exceed 75 Amperes.
    • Inspect crimp: A poor crimp can lead to high resistance and heat.
  • Ulanish/uzishdagi qiyinchilik:
    • Check for debris: Ensure no foreign objects are obstructing the connection.
    • Inspect housing: Verify that the PowerPole housings are not damaged or deformed.

8. Texnik shartlar

BrendAnderson Power mahsulotlari
Model raqami5915-BK
Sim o'lchagichning mosligi10 AWG, 12 AWG
Joriy reyting75 Amperes
Ulagich turiKrimp
Aloqa materialiMis
Izolyatsiya materiallariIzolyatsiya qilinmagan
Paket o'lchamlari6 x 3 x 0.5 dyuym
Element og'irligi0.16 ounces (per 5 pieces)

9. Qo'llab-quvvatlash ma'lumotlari

For further assistance or inquiries regarding Anderson Power Products, please refer to the official manufacturer's website or contact their customer support. Specific warranty information is not provided in the product data.

Ishlab chiqaruvchi: Anderson Power Products, Inc.

Tegishli hujjatlar - 5915-BK

Oldindanview SBE 160 va SBE 320 seriyali SBE® ulagichlarini yig'ish bo'yicha ko'rsatmalar
Anderson Power Products kompaniyasining SBE® 160 va SBE 320 seriyali ikki kutupli akkumulyator ulagichlari uchun batafsil montaj ko'rsatmalari, jumladan reytinglar, siqish, yig'ish va yordamchi kontaktlarni o'rnatish.
Oldindanview Anderson Powerpole PP75 ulagichlari: texnik xususiyatlari, buyurtmasi va aksessuarlari
Anderson Powerpole PP75 ulagichlari uchun batafsil ma'lumotlar jadvali, uning texnik xususiyatlari, sim diapazonlari, korpus turlari, kontaktlar, harorat jadvallari va aksessuarlari. 120 gacha baholangan Amps.
Oldindanview Ma'lumotlar markazlari uchun Saf-D-Grid 3 fazali quvvat ulagichi | Anderson Power Products
Anderson Power Products tomonidan ishlab chiqarilgan Saf-D-Grid 3 fazali ulagichini kashf eting, u kengaytirilgan quvvat zichligi, ixcham dizayn va yuqori voltli quvvatni taklif etadi.tagMa'lumotlar markazlarida AKT uskunalari, PSUlar, PDUlar va UPS tizimlari uchun imkoniyatlar.
Oldindanview Anderson Power Products REACH-(SVHC) deklaratsiyasi - Muvofiqlik haqida ma'lumot
Anderson Power Products kompaniyasining REACH (EC) № 1907/2006-sonli Nizomiga muvofiq juda yuqori tashvishli moddalar (SVHC) bo'yicha deklaratsiyasi, ularning mahsulotlarida 0.1% w/w chegarasidan yuqori SVHClar yo'qligini tasdiqlaydi.
Oldindanview Anderson Power SBS®X-75A Assembly Instructions
Detailed assembly instructions for the Anderson Power SBS®X-75A connector, covering wire preparation, contact crimping, housing assembly, panel mounting, and IP68 protection.
Oldindanview BECKHOFF C9900-K936 & C9900-K937 Power Connector Assembly Instructions
Assembly instructions for BECKHOFF C9900-K936 and C9900-K937 PushPull V4 power connectors. These field-wireable plastic connectors are designed for 2.5 mm² (AWG 14) and 1.5 mm² (AWG 16) cables, featuring a 4-pole, crimp connection, IP65/IP67 protection, and straight male configuration. The document provides step-by-step assembly guidance and detailed technical specifications.