1. Kirish

This manual provides detailed instructions for the proper use, setup, operation, and maintenance of your OWON VDS1022I USB PC Oscilloscope. Please read this manual thoroughly before operating the device to ensure optimal performance and safety. The OWON VDS1022I is a compact, high-performance USB oscilloscope designed for various electrical measurement and analysis tasks, featuring USB isolation for enhanced signal integrity and PC protection.

2. Mahsulot tugadiview

2.1 Paket tarkibi

Upon unpacking, verify that all items listed below are present and in good condition. If any items are missing or damaged, contact your supplier.

OWON VDS1022I Oscilloscope and accessories

Image: The OWON VDS1022I USB PC Oscilloscope, two oscilloscope probes, a USB cable, a software CD, and a quick guide manual are included in the package.

  • OWON VDS1022I USB PC Oscilloscope Unit
  • USB kabeli
  • Osiloskop zondlari (2 dona)
  • Dastur kompakt-disklari
  • Tez qo'llanma

2.2 Asosiy xususiyatlar

  • Up to 25MHz bandwidth and 100MS/s real-time sample stavkasi.
  • 5K record length for detailed waveform capture.
  • Friendly user interface with FFT, X-Y mode, and dual waveform display.
  • Multiple trigger options: edge, video, slope, pulse, and alternate.
  • USB isolation for reduced signal interference and enhanced PC protection.
  • USB bus powering, eliminating the need for an external power adapter.
  • Compact and ultra-thin body design for easy portability.

2.3 Qurilmaning joylashuvi

Familiarize yourself with the various ports and indicators on the oscilloscope unit.

OWON VDS1022I Oscilloscope with labeled ports

Rasm: yon view of the OWON VDS1022I, highlighting the USB Port, Probe Compensation output (5V 1KHz), MULTI Port, Signal Input of Channel 2 (CH2), and Signal Input of Channel 1 (CH1).

  • USB port: Connects to your PC for data transfer and power.
  • Probe Compensation (5V 1KHz): Output for adjusting probe compensation.
  • MULTI Port: Multi-function port for additional capabilities.
  • CH2 (Channel 2): Signal input for the second channel.
  • CH1 (Channel 1): Signal input for the first channel.
OWON VDS1022I Oscilloscope showing front and back with isolation

Rasm: Yuqori va pastki views of the OWON VDS1022I. The bottom view shows the "Isolation" label, indicating the USB isolation feature.

The device features USB isolation, which helps to reduce noise and protect your computer from potential electrical surges from the measurement circuit.

3. O'rnatish bo'yicha qo'llanma

3.1 Dasturiy ta'minotni o'rnatish

  1. Insert the provided software CD into your computer's CD-ROM drive.
  2. Locate and run the setup executable file. Follow the on-screen instructions to install the OWON oscilloscope software and necessary drivers.
  3. Alternatively, download the latest software and drivers from the official OWON website. Ensure you select the correct model (VDS1022I) and operating system.
  4. During installation, ensure that the oscilloscope is NOT connected to the PC until prompted, or until the software installation is complete. This helps ensure proper driver recognition.

3.2 Connecting the Oscilloscope

  1. Connect one end of the supplied USB cable to the USB port on the OWON VDS1022I unit.
  2. Connect the other end of the USB cable to an available USB port on your PC. The device is bus-powered, so no external power adapter is required.
  3. Your operating system should detect the device and, if drivers were installed correctly, recognize it as an OWON VDS1022I oscilloscope.

3.3 Zond ulanishi va kompensatsiyasi

  1. Connect the oscilloscope probes to the CH1 and CH2 input BNC connectors on the device.
  2. Attach the probe ground clip to a known ground point in your circuit.
  3. To compensate the probe, connect the probe tip to the 5V 1KHz Probe Compensation output.
  4. Adjust the compensation screw on the probe body until a flat-top square wave is displayed on the software interface. This ensures accurate signal representation.

4. Foydalanish bo'yicha ko'rsatmalar

4.1 Dasturiy ta'minotni ishga tushirish

After successful installation and connection, launch the OWON oscilloscope application from your desktop shortcut or Start Menu. The software interface will display the waveform acquisition window.

4.2 Asosiy to'lqin shaklidagi displey

  • Vertikal shkala (Volt/Div): Adjust the vertical sensitivity for each channel using the controls in the software. This determines the voltage represented by each vertical division on the display.
  • Gorizontal masshtab (Vaqt/Bo'linish): Adjust the horizontal time base to control the time represented by each horizontal division. This affects the displayed duration of the waveform.
  • Kirish ulanishi: Select DC, AC, or GND coupling for each channel as needed.
    • DC: Displays both AC and DC components of the signal.
    • AC: Blocks the DC component, displaying only the AC component.
    • GND: Disconnects the input signal, displaying a ground reference line.

4.3 Ishga tushirish

Triggering stabilizes repetitive waveforms and captures single-shot events. The VDS1022I supports various trigger modes:

  • Chegara tetigi: Triggers on a rising or falling edge of the input signal at a specified voltage darajasi.
  • Videoni ishga tushirish: Standart video signallarida triggerlar.
  • Nishab tetigi: Triggers on a signal's rise or fall time.
  • Darbeli tetik: Triggers on pulses of specific width.
  • Alternate Trigger: Allows triggering on two different channels alternately.

Adjust the trigger level and mode within the software to achieve a stable waveform display.

4.4 O'lchovlar va tahlil

  • Avtomatik o'lchovlar: The software provides automatic measurements for parameters like Vpp, Vmax, Vmin, Freq, Period, RMS, etc. Select desired measurements from the menu.
  • Kursorlar: Jildan foydalaningtage and time cursors to manually measure specific points on the waveform.
  • FFT (Fast Fourier Transform): Access the FFT function to analyze the frequency components of your signal.
  • XY rejimi: Display the relationship between two signals in X-Y format, useful for phase comparisons or Lissajous figures.

5. Xizmat ko'rsatish

  • Tozalash: Osiloskopning tashqi qismini tozalash uchun yumshoq, quruq matodan foydalaning. Qattiq kirlar uchun ozgina tozalang.amp cloth with mild detergent can be used, ensuring no liquid enters the device.
  • Saqlash: Qurilmani to'g'ridan-to'g'ri quyosh nuri va haddan tashqari haroratdan uzoqda, salqin va quruq joyda saqlang.
  • Probni parvarish qilish: Handle probes carefully. Avoid bending or stressing the cables excessively. Keep probe tips clean.
  • Dasturiy ta'minot yangilanishlari: Periodically check the OWON website for software and firmware updates to ensure optimal performance and access to new features.

6. Muammolarni bartaraf qilish; nosozliklarni TUZATISH

6.1 Device Not Recognized by PC

  • Ensure the USB cable is securely connected to both the oscilloscope and the PC.
  • Verify that the correct drivers have been installed. Reinstall drivers if necessary, following the instructions in Section 3.1.
  • Kompyuteringizdagi boshqa USB portiga ulanishga harakat qilib ko'ring.
  • Kompyuteringizni qayta ishga tushiring va qaytadan urinib ko'ring.

6.2 No Waveform Display or Unstable Waveform

  • Check probe connections to the device and the circuit under test. Ensure ground clips are properly connected.
  • Verify that the input coupling (DC/AC/GND) is set appropriately for your signal.
  • Adjust the vertical (Volts/Div) and horizontal (Time/Div) scales to match the expected signal characteristics.
  • Adjust the trigger level and trigger mode. An unstable waveform often indicates an incorrect trigger setting.
  • Ensure the signal source is active and producing a signal within the oscilloscope's measurement range.

6.3 Software Issues or Crashes

  • Ensure your operating system meets the minimum requirements for the OWON software.
  • Update the software to the latest version from the OWON websayt.
  • Close other demanding applications that might be consuming system resources.
  • If issues persist, try reinstalling the software.

6.4 Limited Bandwidth or Signal Distortion

  • The VDS1022I has a 25MHz bandwidth. Signals exceeding this frequency may be attenuated or distorted.
  • Ensure probes are correctly compensated (refer to Section 3.3).
  • For high-frequency measurements, ensure proper grounding and minimize cable lengths to reduce noise.

7. Texnik shartlar

OWON VDS1022I Oscilloscope dimensions

Image: Dimensions of the OWON VDS1022I oscilloscope, showing approximate measurements of 180mm (7.09in) length, 125mm (4.92in) width, and 23mm (0.91in) thickness.

ParametrQiymat
Tarmoqli kengligi25 MGts
Kanallar2 + 1 (external trigger)
Sample Rate100 MS/s (real-time)
Horizontal Scale (s/div)5 ns/div ~ 100 s/div (1-2-5 step)
Ko'tarilish vaqti≤ 14 ns
Rekord uzunligi5K points
Kirish ulanishiDC, AC, GND
Kirish empedansi1 MΩ ±2%, in parallel with 10 pF ±5 pF
Channels Isolation50Hz: 100:1, 10MHz: 40:1
Maksimal kirish hajmitage400V (PK - PK) (DC+AC, PK - PK)
DC daromad aniqligi±3%
Zondni susaytirish omili1X, 10X, 100X, 1000X
LF Respond (AC, -3dB)≥ 5Hz (at input, AC coupling, -3dB)
Sampling Rate / Relay vaqtining aniqligi150 p
Interpolatsiyasin(x) / x
Vertikal ruxsat (A/D)8 bit (bir vaqtning o'zida 2 ta kanal)
Vertikal sezgirlik5 mV/div ~ 5 V/div
Aloqa interfeysiUSB 1.1 (isolation)
Mahsulot o'lchamlari6.69 x 4.72 x 0.71 inches (170 x 120 x 18 mm); 1.46 Pounds (0.66 kg)
Ishlab chiqaruvchiOWON

8. Kafolat va qo'llab-quvvatlash

OWON products are designed and manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your product or visit the official OWON website. In case of technical issues, questions, or service requests, please contact OWON customer support through their official channels. Keep your purchase receipt as proof of purchase for warranty claims.

Tegishli hujjatlar - VDS1022I

Oldindanview OWON TAO3000 seriyali qo'lda ishlatiladigan osiloskoplar foydalanuvchi qo'llanmasi
OWON TAO3000 to'rt kanalli seriyali qo'lda osiloskoplar uchun foydalanuvchi qo'llanmasi, batafsil ishlashi, xususiyatlari, texnik xususiyatlari va muammolarni bartaraf etish.
Oldindanview OWON HDS200 seriyali qo'lda osiloskop uchun tezkor qo'llanma
Ushbu tezkor qo'llanma OWON HDS200 seriyali qo'lda ishlatiladigan osiloskopni ishlatish bo'yicha muhim ma'lumotlarni taqdim etadi. Unda mahsulotni sertifikatlash, xavfsizlik choralari, osiloskop va multimetr funktsiyalaridan foydalanish bo'yicha batafsil ko'rsatmalar, to'lqin shakli generatorining ishlashi, keng tarqalgan muammolarni bartaraf etish va texnik xizmat ko'rsatish tartiblari qamrab olingan.
Oldindanview OWON PDS seriyali ko'chma LCD raqamli saqlash osiloskopi foydalanuvchi qo'llanmasi
OWON PDS seriyali ko'chma LCD raqamli saqlash osiloskopi uchun xususiyatlar, ishlash, xavfsizlik, muammolarni bartaraf etish va texnik xususiyatlarni qamrab oluvchi keng qamrovli foydalanuvchi qo'llanmasi.
Oldindanview Owon SDS200S Series Digital Storage Oscilloscope User Manual
User manual for the Owon SDS200S Series Digital Storage Oscilloscope, covering setup, operation, features, and troubleshooting.
Oldindanview OWON SDS1022 / SDS1102 Digital Storage Oscilloscope User Manual - Comprehensive Guide
This user manual provides detailed instructions and specifications for the OWON SDS1022 and SDS1102 Digital Storage Oscilloscopes, covering setup, operation, advanced features, troubleshooting, and technical details.
Oldindanview OWON HDS200 seriyali portativ osiloskop foydalanuvchi qo'llanmasi - foydalanish va texnik xususiyatlar
Ushbu keng qamrovli foydalanuvchi qo'llanmasi OWON HDS200 Dual Channel Series portativ osiloskoplarini, jumladan HDS272(S) va HDS242(S) modellarini ishlatish bo'yicha batafsil ko'rsatmalarni taqdim etadi. U xavfsizlik ma'lumotlarini, umumiy tekshiruv, osiloskop, multimetr va ixtiyoriy to'lqin shakli generatori funktsiyalarini, shuningdek, texnik xususiyatlar va texnik ko'rsatmalarni o'z ichiga oladi.