Renogy SUNDCCB32MN1P

Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker User Manual

Model: SUNDCCB32MN1P

1. Kirish

Ushbu qo'llanmada Renogy Suntree 32 uchun ko'rsatmalar berilgan Amp Single-Pole DC Circuit Breaker. This device is designed to protect DC electrical installations against overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms to ensure reliability and safety. The circuit breaker automatically disconnects the electrical circuit upon fault detection, preventing wire damage and fire hazards. It can also be manually operated for system maintenance. Its reversible connection design allows for wiring in either direction, supporting bidirectional current flow. A built-in indicator window provides immediate visual confirmation of the circuit breaker's contact position. The buckle design facilitates easy installation on standard DIN rails.

Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker

1-rasm: Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker. This image shows the front and side view of the circuit breaker with its green toggle switch.

2. Xavfsizlik bo'yicha ko'rsatmalar

Please read and understand all safety instructions before installing or operating the circuit breaker. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Mahsulot xususiyatlari

Ichki view of circuit breaker showing components

2-rasm: Internal components of the circuit breaker, illustrating the thermal and magnetic tripping mechanisms for reliable and safe operation.

Circuit breaker durability metrics

3-rasm: Durability specifications for the circuit breaker, highlighting a mechanical life of 20,000 operations and an electrical life of 10,000 operations, along with high electrical conductivity.

4. Texnik shartlar

AtributQiymat
BrendRenogiya
Model raqamiSUNDCCB32MN1P
Joriy reyting32 Amps
O'chirish to'xtatuvchisi turiStandart
O'rnatish turiDIN relsli tog'i
Polyaklar soni1
MaterialMis
Element og'irligi3.84 untsiya
Mahsulot o'lchamlari3.2 x 3 x 0.7 dyuym
UPC810009719663
Circuit breaker dimensions

4-rasm: Physical dimensions of the Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker, showing a length of 3.2 inches, a width of 0.7 inches, and a height of 3.2 inches, with a weight of 4.2 ounces.

Sizing tips for circuit breakers

5-rasm: Guidelines for selecting the correct circuit breaker size for controllers, inverters, DC devices, and solar panels. It outlines calculations based on continuous operating current and short-circuit current.

5. O'rnatish

5.1 Mounting on DIN Rail

  1. Ensure the DIN rail is securely mounted within the breaker box or enclosure.
  2. Align the circuit breaker's top slot with the top edge of the DIN rail.
  3. Press the circuit breaker firmly against the DIN rail until the buckle mechanism clicks into place, securing it.
  4. Verify the circuit breaker is firmly attached and does not wobble.
Diagram showing how to install circuit breaker on DIN rail

6-rasm: Step-by-step diagram illustrating the quick installation process of the circuit breaker onto a standard DIN rail using its buckle design. The diagram shows aligning the slot, pressing, and securing with a click.

5.2 Simli ulanishlar

The Renogy Suntree DC Circuit Breaker is designed for reversible connection, meaning it can be wired in either direction. However, it is crucial to maintain correct polarity for DC systems.

Circuit breaker wiring connection diagram

7-rasm: Diagram showing the connection points for the circuit breaker, indicating the positive terminal at the top and the corresponding connection at the bottom. This illustrates the reversible connection capability.

6. Operatsiya

6.1 Yoqish/o'chirish

6.2 Automatic Tripping

In the event of an overload or short circuit, the circuit breaker will automatically trip to the "OFF" position, interrupting the circuit and protecting connected equipment. The indicator window will show red.

6.3 Resetting the Circuit Breaker

After an automatic trip, identify and resolve the cause of the fault (e.g., remove overload, fix short circuit) before attempting to reset the breaker. Once the fault is cleared, push the toggle switch downwards to fully reset it, then push it upwards to the "ON" position.

Circuit breaker ON and OFF indicators

8-rasm: Visual representation of the circuit breaker's indicator window, showing green for "ON" status and red for "OFF" status, providing clear operational feedback.

7. Xizmat ko'rsatish

The Renogy Suntree DC Circuit Breaker requires minimal maintenance. Regular inspections are recommended to ensure optimal performance and safety.

Note: Do not attempt to open or repair the circuit breaker. Refer to qualified personnel for any issues beyond basic inspection and cleaning.

8. Muammolarni bartaraf qilish; nosozliklarni TUZATISH

MuammoMumkin sababYechim
O'chirish to'xtatuvchisi tez-tez ishlamay qoladi.Elektr zanjiridagi ortiqcha yuk, qisqa tutashuv yoki nosoz jihoz.Reduce the load on the circuit. Inspect wiring and connected devices for short circuits. Disconnect faulty appliances.
O'chirish to'xtatuvchisi qayta o'rnatilmaydi.Persistent fault (overload/short circuit) or internal damage to the breaker.Ensure the fault is completely cleared. If the fault is cleared and it still doesn't reset, the breaker may be damaged and require replacement.
Circuit breaker feels hot.Overload, loose connections, or undersized wiring.Check for overloads. Tighten all terminal connections. Verify wire gauge is appropriate for the current.
No power to the circuit, but breaker is ON.Faulty wiring upstream/downstream, or internal breaker failure.Check continuity of wiring. If wiring is intact, the breaker may be faulty and require replacement.

9. Kafolat va qo'llab-quvvatlash

Renogy products are manufactured with high-quality materials and craftsmanship. For specific warranty information, please refer to the warranty card included with your product or visit the official Renogy website. For technical support, product inquiries, or assistance with troubleshooting, please contact Renogy customer service through their official channels.

Renogy rasmiysi Websayt: www.renogy.com

Please have your model number (SUNDCCB32MN1P) and purchase date available when contacting support.

Tegishli hujjatlar - SUNDCCB32MN1P

Oldindanview Renogy 500A Combiner Box (Advanced Version) User Manual
This user manual provides comprehensive instructions for the Renogy 500A Combiner Box (Advanced Version), covering its features, installation, wiring diagrams, specifications, maintenance, troubleshooting, and safety guidelines for solar power systems.
Oldindanview Renogy Off-Grid Solar Kit General Manual: Installation and Operation Guide
This manual provides comprehensive instructions for installing, wiring, and maintaining the Renogy Off-Grid Solar Kit. Learn about safety precautions, mounting systems, battery configurations, and system connections for reliable off-grid power.
Oldindanview Renogy Off-Grid quyosh energiyasi to'plami foydalanuvchi qo'llanmasi: O'rnatish, simlarni ulash va o'rnatish bo'yicha qo'llanma
Renogy Off-Grid Quyosh energiyasi to'plamlari uchun batafsil foydalanuvchi qo'llanmasi, unda o'rnatish, simlarni ulash, o'rnatish tizimlari (Z-braket, temir yo'l, ustun), batareya konfiguratsiyalari, xavfsizlik choralari va RVlar, qayiqlar va tarmoqdan tashqari quvvat tizimlari uchun ANL sug'urtalaridan foydalanish yoritilgan.
Oldindanview Renogy Battery Shunt 300 foydalanuvchi uchun qo'llanma
Renogy Battery Shunt 300 uchun batafsil foydalanuvchi qo'llanmasi, quyosh energiyasi va tarmoqdan tashqari tizimlarda aqlli batareya monitoringi uchun o'rnatish, ishlatish, sozlash va muammolarni bartaraf etish bo'yicha ko'rsatmalar beradi.
Oldindanview Renogy ONE Core tezkor qo'llanmasi | O'rnatish va ishlatish
Renogy ONE Core (RSHGWSN-W02W-G3) uchun qisqacha qo'llanma, unda o'rnatish, ulanish va asosiy ishlash qoidalari yoritilgan. Optimal ishlash uchun Renogy ONE Core-ni qanday sozlashni bilib oling.
Oldindanview Renogy ONE Core User Manual: Comprehensive Guide to Energy Monitoring and Smart Home Integration
This user manual provides detailed instructions for the Renogy ONE Core, covering installation, operation, features like RV leveling and smart home integration, troubleshooting, and technical specifications. Learn how to monitor and manage your energy systems effectively.