HPE MR408i-o

HPE MR408i-o Gen11 saqlash kontrolleri foydalanuvchi qo'llanmasi

Model: MR408i-o | Brand: HPE

1. Kirish

The HPE MR408i-o Gen11 Storage Controller is a high-performance, versatile PCIe Gen4.0 storage controller designed for data centers. Based on Broadcom MegaRAID technology, it provides robust data management, performance, and security for mission-critical applications. This controller supports various RAID levels and HBA/pass-through modes, offering flexibility for diverse server environments.

2. Xavfsizlik ma'lumotlari

O'rnatish va ishlatishda quyidagi xavfsizlik choralariga rioya qiling:

  • Always disconnect power from the server before installing or removing any components.
  • Wear an anti-static wrist strap to prevent electrostatic discharge (ESD) damage to the controller and other server components.
  • Handle the controller by its edges; avoid touching the components or connectors directly.
  • Haddan tashqari qizib ketishining oldini olish uchun server shassisida to'g'ri shamollatishni ta'minlang.
  • Refer to your server's documentation for specific installation guidelines and safety warnings.

3. Paket tarkibi

Paketda barcha elementlar mavjudligiga ishonch hosil qiling:

  • HPE MR408i-o Gen11 Storage Controller
  • Hujjatlar (Tezkor ishga tushirish bo'yicha qo'llanma, Kafolat ma'lumotlari)
  • Any included cables (e.g., SlimSAS cables, if applicable to your specific SKU)

If any items are missing or damaged, contact your vendor or HPE support immediately.

4. Mahsulot tugadiview

The HPE MR408i-o Gen11 Storage Controller features a PCI Express 4.0 x8 host interface, supporting Serial ATA/600 and 12Gb/s SAS drives. It includes 4GB of Flash Backed Cache for data protection and enhanced performance. The controller is equipped with one 1x8 LP SlimSAS connector for internal drive connectivity.

HPE MR408i-o Gen11 Storage Controller, front view

Figure 4.1: HPE MR408i-o Gen11 Storage Controller (Main View). This image displays the primary components and connectors of the controller card.

HPE MR408i-o Gen11 Storage Controller, angled view

Figure 4.2: HPE MR408i-o Gen11 Storage Controller (Angled View). This image provides an alternative perspective of the controller, highlighting its form factor and additional details.

5. Sozlash

5.1. Uskunani o'rnatish

  1. Power down the server and disconnect all power cables.
  2. Open the server chassis according to the manufacturer's instructions.
  3. Locate an available PCI Express 4.0 x8 slot on the server motherboard.
  4. Carefully insert the HPE MR408i-o controller into the PCIe slot, ensuring it is fully seated. Secure the controller with the retention mechanism or screw.
  5. Connect the internal drives (SAS or SATA) to the 1x8 LP SlimSAS port on the controller using appropriate cables. Refer to your server's documentation for internal cabling routes.
  6. Close the server chassis and reconnect power cables.

5.2. Drayv o'rnatish

After hardware installation, power on the server. The operating system may automatically detect the new hardware. If not, or for optimal performance, install the latest drivers from the HPE support website. Drivers are available for:

  • Windows Server
  • Red Hat Enterprise Linux
  • SuSE Linux Enterprise Server
  • Ubuntu Linux
  • VMware ESXi
  • CentOS

6. Operatsion

6.1. RAID konfiguratsiyasi

The HPE MR408i-o controller supports various RAID levels to optimize data redundancy and performance:

  • RAID 0: Striping (performance, no redundancy)
  • RAID 1: Mirroring (redundancy, no striping)
  • RAID 5: Striping with distributed parity (performance and redundancy)
  • RAID 6: Striping with dual distributed parity (enhanced redundancy)
  • RAID 10: Mirrored stripes (performance and redundancy)
  • RAID 50: Striped RAID 5 sets (higher performance and capacity than RAID 5)
  • RAID 60: Striped RAID 6 sets (higher performance and capacity than RAID 6)

Configuration is typically performed through the controller's BIOS utility during server boot-up or via a software management utility provided by HPE or Broadcom (MegaRAID Storage Manager). Consult the software documentation for detailed instructions on creating and managing RAID volumes.

6.2. HBA / Pass-Through Mode

The controller can also operate in HBA (Host Bus Adapter) or pass-through mode, allowing the operating system to directly manage individual drives. This mode is often preferred in virtualized environments or software-defined storage solutions. Refer to the controller's configuration utility to enable or disable HBA mode.

7. Xizmat ko'rsatish

Regular maintenance ensures optimal performance and longevity of your storage controller:

  • Dasturiy ta'minotni yangilash: HPE qo'llab-quvvatlashini vaqti-vaqti bilan tekshirib turing website for the latest firmware updates for your controller. Firmware updates can provide performance enhancements, bug fixes, and compatibility improvements.
  • Haydovchi yangilanishlari: Ensure your operating system drivers for the controller are up-to-date.
  • Tizim monitoringi: Utilize server management tools to monitor the health and status of your RAID arrays and individual drives.
  • Atrof-muhit nazorati: Maintain a stable operating environment with appropriate temperature and humidity levels to prevent hardware degradation.

8. Muammolarni bartaraf qilish; nosozliklarni TUZATISH

If you encounter issues with your HPE MR408i-o controller, consider the following steps:

  • Aniqlanish yo'q: Ensure the controller is properly seated in the PCIe slot and that the server's BIOS/UEFI settings are configured to detect PCIe devices. Verify power connections.
  • Drive Issues: Check drive cables and power connections. Verify that drives are compatible with the controller. Use the controller's management utility to check drive status.
  • RAID Array Failure: If a drive in a redundant array fails, replace it promptly. The controller should automatically begin rebuilding the array. Monitor the rebuild process through the management utility.
  • Performance Problems: Ensure drivers and firmware are up-to-date. Check for any background processes consuming resources. Verify drive health.
  • Operating System Errors: Consult the operating system's event logs for error messages related to the storage controller.

For persistent issues, gather system logs and contact HPE technical support.

9. Texnik shartlar

XususiyatTavsif
ModelMR408i-o
Xost interfeysiPCI Express 4.0 x8
Nazoratchi turiSerial ATA/600, 12Gb/s SAS
RAID qo'llab-quvvatlanadiHa
RAID darajalari0, 1, 5, 6, 10, 50, 60
Data Backup TypeFlash qo'llab-quvvatlanadigan kesh
Kesh xotirasi4 GB
Total SAS Ports1
SAS Connector Details1x8 LP SlimSAS
Qurilma qo'llab-quvvatlanadiServer
Operatsion tizimni qo'llab-quvvatlashWindows Server, Red Hat Enterprise Linux, SuSE Linux Enterprise Server, Ubuntu Linux, VMware ESXi, CentOS
Mahsulot o'lchamlari9.9 x 8.8 x 2.5 dyuym
Element og'irligi4.4 funt
Ishlab chiqaruvchi qism raqamiP58335B21
Model raqami0190017623740

10. Kafolat va qo'llab-quvvatlash

This HPE product is covered by a limited warranty. For detailed warranty terms and conditions, please refer to the documentation included with your product or visit the official HPE website. For technical assistance, driver downloads, firmware updates, and additional support resources, please visit the HPE support portal:

HPE qo'llab-quvvatlashi Websayt

Tegishli hujjatlar - MR408i-o

Oldindanview HPE ProLiant DL20 Gen11 System Configuration Guide
This document provides a detailed system configuration overview for the HPE ProLiant DL20 Gen11 server, including specifications, component options, and model variations. It covers processors, memory, storage, networking, and other essential hardware components to help users understand and configure their server.
Oldindanview HPE ProLiant DL20 Gen11 System Configuration Diagram
This document provides a detailed system configuration diagram for the HPE ProLiant DL20 Gen11 server, outlining various component options and specifications.
Oldindanview HPE ProLiant DL320 Gen11 System Configuration Diagram
This document provides a detailed system configuration diagram for the HPE ProLiant DL320 Gen11 server, outlining various component options and specifications. It covers processor types, memory configurations, storage options (LFF and SFF), network adapters, expansion slots, and power supplies, along with specific details for Smart Choice models.
Oldindanview HPE ProLiant ML30 Gen11 System Configuration Diagram
Detailed system configuration diagram for the HPE ProLiant ML30 Gen11 server, including various models, processors, memory, storage options, and connectivity.
Oldindanview HPE ProLiant DL360 Gen11 System Configuration Diagram
This document provides a detailed system configuration diagram for the HPE ProLiant DL360 Gen11 server, outlining various models, processor options, memory configurations, storage bays, network adapters, and expansion slots. It serves as a comprehensive guide for understanding the server's architecture and available options.
Oldindanview HPE ProLiant ML110 Gen11 System Configuration Diagram
Detailed system configuration diagram for the HPE ProLiant ML110 Gen11 server, including processor options, memory configurations, storage bays, and network adapters.